Case Study

Nickel flux validates groundwater model, prompting risk-based management

_DSC7812
iFLUX Sampler
Nickel & CVOC's 
  metal treatment
  antea group
   Belgium

Our value

Residual source strength determination

Successful groundwater model calibration

Accepted Risk-Based Management approach

Due to former surface treatment activities of metals, the subsoil was polluted. The contamination consists of Nickel and CVOC’s from just beneath the concrete slab to 4m-bgl. The unsaturated source zone has been removed. No DNAPL seemed to be present in the saturated zone, but also no natural attenuation of the CVOC’s seemed to happen.

Sampling

We used mass fluxes to determine the source and plume strengths. A groundwater and contaminant transport model had been built by Antea and was further calibrated by the iFLUX mass flux results.

  1. Installation of 2 control planes, one in the source and one in the plume zone
  2. Every control plane consisted of 3 to 4 clusters of respectively 3 monitoring wells at 3 different depths
  3. A total of 44 iFLUX cartridges have been exposed
  4. Exposure time: 10 weeks
_DSC7776

"Flux measurements allow you to determine the residual source strength and optimize the remediation strategy accordingly"

Challenges

How to assess and control groundwater migration risk:
  • Evolution of contaminated groundwater plume?
  • Migration or contaminant spreading?
  • Verify groundwater model
  • Risk-based management approach feasible?

The Solutions

iFLUX provides insight in dynamic and complex process:
  • Assessment of source strength evolution over time
  • Measuring movement of contaminants
  • Look for preferential pathways related to heterogeneous soil permeability
  • Verify possibility of focused mitigation measure based on underground behavior of Nickel and CVOC's separately.
site map

After the first iteration a stable Nickel plume was confirmed. Most measured values were less than 0,5 mg/m²/day, which was a factor of 30 lower than the water flux expressed in cm/d at corresponding depths. Because of this, further active remediation of residual Nickel contamination was no longer deemed necessary by the supervising authority. A risk- based management approach was approved for coming years, which could probably avoid an extensive and expensive remediation process.

Subsequently, in the second and third iteration, only CVOC’s were measured. Before the flux measurements, unexpected results were found in the concentration measurements (in P43). The stratification of the pollution was different than expected.

By adding flux measurements, it was possible to interpret these results with more certainty and to adapt the contaminant transport model accordingly. The groundwater flow model has been calibrated according to these results.

Conclusions:
  • Relevant CVOC's mass present and migrating down gradient. Nickel mass is stable.
  • Preferential pathways related to heterogeneous soil permeability found.
  • Focused mitigation measures possible. Remedial monitoring and design needs to be differentiated for stable Nickel and migrating CVOC's
measured contaminant mass flux

Figure: Measured mass fluxes (mg/m²/day) at different depths (in meters)

measured groundwater flux

Figure: Measured groundwater flux (cm/day per depth) and nickel (mg/m²/day) at different depths.